Kazakhstan is our home, introducing reliable advanced technologies, we will make it modern and strong!
Leave a request

Three-phase UPS from 60 to 200 kVA
This new generation of transformerless UPS solves all the major problems of IT managers and office managers. Cost reduction and 100% uptime are their top priorities. Multi Sentry provides the lowest cost of ownership of any UPS system, energy efficiency, scalable flexibility, high availability and easy maintenance.
Multi Sentry Characteristics:
| MODELS | MST 60 | MST 80 | MST 100 | MST 125 | MST 160 | MST 200 |
| INPUT | ||||||
| Rated voltage (V) | 380 / 400 / 415 three-phase + N | |||||
| Rated frequency (Hz) | 50 / 60 | |||||
| Voltage tolerance | 400 ±20% @ full load1 | |||||
| Frequency tolerance [Hz] | 40 – 72 | |||||
| Power factor @ full load | 0.99 | |||||
| Current distortion | THDI ≤3% | THDI ≤2.5% | ||||
| BYPASS | ||||||
| Rated voltage [V] | 380 / 400 / 415 three-phase + N | |||||
| Number of phases | 3 + N | |||||
| Voltage tolerance (Ph-N) [V] | 180 / 264 (selectable) | |||||
| Rated frequency [Hz] | 50 or 60 (selectable) | |||||
| Frequency tolerance | ±5% (selectable) | |||||
| Bypass overload | 125% for 60 min., 150% for 10 min | |||||
| OUTPUT | ||||||
| Nominal power [kVA] | 60 | 80 | 100 | 125 | 160 | 200 |
| Active power [kW] | 54 | 72 | 90 | 112.5 | 160 | 200 |
| Power factor | 0.9 | 1 | ||||
| Number of phases | 3 + N | |||||
| Rated voltage [V] | 380 / 400 / 415 three-phase + N (selectable) | |||||
| Static variation | ±1% | |||||
| Dynamic variation | ±3% | |||||
| Crest factor [lpeack/lrms] | 3:1 | |||||
| Voltage distortion | ≤1% with linear load / ≤3% with non-linear load | |||||
| Frequency [Hz] | 50 / 60 | |||||
| Frequency stability during battery operation | 0.01% | |||||
| BATTERIES | ||||||
| Type | VRLA AGM/GEL/NiCd/Li-ion/Supercaps | |||||
| Recharge time | 6 h | |||||
| OVERALL SPECIFICATIONS | ||||||
| Weight without batteries [kg] | 190 | 200 | 220 | 250 | 450 | 460 |
| Dimensions (WxDxH) [mm] | 500x830x1600 | 650×830 x1600 | 840x1035x1900 | |||
| Communications | 3 slots for communications interface / USB / RS232 | |||||
| Ambient temperature for the UPS | 0 °C – +40 °C | |||||
| Recommended temperature for battery life | +20 °C – +25 °C | |||||
| Range of relative humidity | 5-95% non-condensing | |||||
| Colour | Dark grey RAL 7016 | |||||
| Noise level at 1 m [dBA±2] (SMART ACTIVE ) | <63 | <50 | ||||
| IP rating | IP20 | |||||
| SMART ACTIVE efficiency | up to 99% | |||||
| Standards | European directives: L V 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111 | |||||
| Moving the UPS | castors (60 – 200 kVA) | |||||
| 1 For wider tolerance conditions apply | ||||||