The Multi Sentry MST series of uninterruptible power supplies (UPS) ranging from 60 to 200 kVA are designed to provide reliable power to critical equipment.

Three-phase UPS from 60 to 200 kVA

This new generation of transformerless UPS solves all the major problems of IT managers and office managers. Cost reduction and 100% uptime are their top priorities. Multi Sentry provides the lowest cost of ownership of any UPS system, energy efficiency, scalable flexibility, high availability and easy maintenance.

Multi Sentry Characteristics:

MODELSMST 60MST 80MST 100MST 125MST 160MST 200
INPUT
Rated voltage (V)380 / 400 / 415 three-phase + N
Rated frequency (Hz)50 / 60
Voltage tolerance400 ±20% @ full load1
Frequency tolerance [Hz]40 – 72
Power factor @ full load0.99
Current distortionTHDI ≤3%THDI ≤2.5%
BYPASS
Rated voltage [V]380 / 400 / 415 three-phase + N
Number of phases3 + N
Voltage tolerance (Ph-N) [V]180 / 264 (selectable)
Rated frequency [Hz]50 or 60 (selectable)
Frequency tolerance±5% (selectable)
Bypass overload125% for 60 min., 150% for 10 min
OUTPUT
Nominal power [kVA]6080100125160200
Active power [kW]547290112.5160200
Power factor0.91
Number of phases3 + N
Rated voltage [V]380 / 400 / 415 three-phase + N (selectable)
Static variation±1%
Dynamic variation±3%
Crest factor [lpeack/lrms]3:1
Voltage distortion≤1% with linear load / ≤3% with non-linear load
Frequency [Hz]50 / 60
Frequency stability during battery operation0.01%
BATTERIES
TypeVRLA AGM/GEL/NiCd/Li-ion/Supercaps
Recharge time6 h
OVERALL SPECIFICATIONS
Weight without batteries [kg]190200220250450460
Dimensions (WxDxH) [mm]500x830x1600650×830 x1600840x1035x1900
Communications3 slots for communications interface / USB / RS232
Ambient temperature for the UPS0 °C – +40 °C
Recommended temperature for battery life+20 °C – +25 °C
Range of relative humidity5-95% non-condensing
ColourDark grey RAL 7016
Noise level at 1 m [dBA±2] (SMART ACTIVE )<63<50
IP ratingIP20
SMART ACTIVE efficiencyup to 99%
StandardsEuropean directives: L V 2014/35/EU low voltage Directive EMC 2014/30/EU electromagnetic compatibility Directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2; RoHS compliant Classification in accordance with IEC 62040-3 (Voltage Frequency Independent) VFI – SS – 111
Moving the UPScastors (60 – 200 kVA)
1 For wider tolerance conditions apply
To catalog
Download brochure

Похожие товары

GP Series

GP series batteries (12V, 33-200 Ah) provide long life and excellent discharge performance, ideal for UPS and inverter applications.

  • Improved discharge performance (40% better than conventional batteries).
  • Minimal operating costs due to AGM design.
  • Durability up to 12 years.

Next

FOX Series (9-20kVA)

Diesel generator sets of FOX series with capacity from 9 to 20 kVA are designed for reliable backup and main power supply.

  • Reliable control system.
  • Noise reduction with quality soundproofing.
  • Durable galvanized steel housing.

Next