  • Shelter cooling
  • Direct Free Cooling
  • Installation in the shelter
  • Installation outside the shelter

Solutions for Free-Air units

  • Shelter cooling
  • Direct Free Cooling.
  • Installation in the shelter
  • Installation outside the shelter

Benefits

  • Energy efficient Free Cooling solution that can be retrofitted in existing systems.
  • The return on investment for the retrofit is achieved especially quickly in base stations, where comfort air conditioning units are running 24 hours a day.
  • The Free-Air units are plug and play and therefore immediately ready for connection and use.

Technical Data

Cooling capacity total (kW)

14

Airflow volume (m3/h)

4,500

Sizes

5

The FCL is installed outside the container, so that the entire interior space can be used for IT equipment. Full access from the outside for maintenance purposes.

Features

  • Ready for operation on the very first day – easy mechanical and electrical installation
  • Simple integration of existing comfort air conditioning units
  • Outside temperature value for Free Cooling can be defined as you wish
  • Speed-controlled EC fan
  • Full service accessibility from the front
  • Measures DC power consumption
  • G4 air filters: The FCL35/60-IN is equipped with a pocket filter, which provides a larger filter area (2 m2). This reduces pressure drops and extends service intervals
  • Insulated, powder-coated housing of galvanized sheet steel
  • The filter alarm can be triggered either by differential pressure or based on a manually adjustable fan operating time

Control and monitoring

The Free-Air units are monitored and controlled by the C102 microprocessor. Comfort air conditioning units can be integrated in the existing air conditioning system and also actuated by the C102 controller.

  • The integrated relays enable the C102 to control and monitor up to two connected comfort air conditioning units
  • It directly measures the energy consumption of the Free-Air units and records the operating hours of the comfort air conditioning units
  • It provides backup ventilation upon failure of the main power supply or a fault in the comfort air conditioning units
  • 48 VDC power supply enables it to be used for emergency backup ventilation
  • Monitoring: ModBus onboard, further protocols via WIB 1000

WIB 1000

WIB 1000 is user-friendly and offers easy data exchange, monitoring and worldwide suitability.

  • Ongoing retrieval of data from the controller
  • Ethernet interface
  • Easy connection to existing building management system
  • Simultaneous HTTP and SNMP
  • Easy, fast configuration from a laptop
    • Compatible with all common BMS systems
    • Communication via SNMP and HTTP IP protocols