CyberAir 2 - Innovation For Maximum Energy-efficiency

The CyberAir 2 precision air-conditioning system with DFC conditions the air in large computer and equipment rooms with a heat load of over 20 kW up to 60 % more economically than conventional compressor cooling systems.

CyberAir 2 is the world’s first precision air-conditioning system that considers heat load in computer rooms and seasonally varying ambient temperatures. It automatically selects the optimal operation mode for each case. In cool weather, the optional DFC automatic air-conditioning technology makes use of thrifty dynamic free cooling with outside air. Energy-intensive compressor cooling (DX) is only switched on when absolutely necessary. For this purpose, all units are equipped with speed-controlled EC fans and electronic expansion valves.

In addition to the DFC version described above, STULZ also offers the CyberAir 2 series in the versions A, G, GE, ACW, GCW, CW and CW2. CyberAir 2 units are available in six sizes. They require floor space 1000 mm to 2900 mm wide and only 890 mm deep. And the planner has a choice of three coolants - R407C, R410A or R134a.

CyberAir 2 DX and Dual-Fluid Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/ACW/GCW
Direction of air downflow / upflow
Sizes 1-3

CyberAir 2 DX and Dual-Fluid Units, dual-circuit

Cooling capacity 40 kW to 105 kW
Cooling systems A/G/ACW/GCW
Direction of air downflow / upflow
Sizes 3-5

CyberAir 2 LowNoise DX and GE Units, single-circuit

Cooling capacity 18 kW to 54 kW
Cooling systems A/G/GE
Direction of air downflow / upflow
Sizes 2-4

CyberAir 2 LowNoise DX Units, dual-circuit

Cooling capacity 41 kW to 73 kW
Cooling systems A/G
Direction of air downflow / upflow
Sizes 4-5

CyberAir 2 LowNoise GE Units, dual-circuit

Cooling capacity 41 kW to 104 kW
Cooling systems GE
Direction of air downflow / upflow
Sizes 4-5

CyberAir CW

Cooling capacity 30 kW - 146 kW; 212 kW
Cooling systems CW
Direction of air downflow / upflow*
Sizes 1-5; 7

*Size 7 is only available in downflow version

CyberAir CW2

Cooling capacity 26 kW to 103 kW
Cooling systems CW2
Direction of air downflow / upflow
Sizes 1-5

Dimensions (WxHxD in mm)

Size 1 1000 x 1980 x 890
Size 2 1400 x 1980 x 890
Size 3 1750 x 1980 x 890
Size 4 2150 x 1980 x 890
Size 5 2550 x 1980 x 890
Size 7 2900 x 1980 x 890